Influence of Connection Geometry and SVC-IVC Flow Rate Ratio on Flow Structures within the Total Cavopulmonary Connection: A Numerical Study
Author:
Khunatorn Yottana1, Mahalingam Shankar2, DeGroff Curt G.3, Shandas Robin13
Affiliation:
1. Department of Mechanical Engineering, University of Colorado, Boulder, CO 80309-0427 2. Department of Mechanical Engineering, University of California, Riverside, CA 92521 3. Cardiovascular Flow Research Laboratory, The Children’s Hospital/University of Colorado Health Sciences Center, Denver, CO 80218
Abstract
The total cavopulmonary connection (TCPC) is a palliative cardiothoracic surgical procedure used in patients with one functioning ventricle that excludes the heart from the systemic venous to pulmonary artery pathway. Blood in the superior and inferior vena cavae (SVC, IVC) is diverted directly to the pulmonary arteries. Since only one ventricle is left in the circulation, minimizing pressure drop by optimizing connection geometry becomes crucial. Although there have been numerical and in–vitro studies documenting the effect of connection geometry on overall pressure drop, there is little published data examining the effect of SVC-IVC flow rate ratio on detailed fluid mechanical structures within the various connection geometries. We present here results from a numerical study of the TCPC connection, configured with various connections and SVC:IVC flow ratios. The role of major flow parameters: shear stress, secondary flow, recirculation regions, flow stagnation regions, and flow separation, was examined. Results show a complex interplay among connection geometry, flow rate ratio and the types and effects of the various flow parameters described above. Significant changes in flow structures affected local distribution of pressure, which in turn changed overall pressure drop. Likewise, changes in local flow structure also produced changes in maximum shear stress values; this may have consequences for platelet activation and thrombus formation in the clinical situation. This study sheds light on the local flow structures created by the various connections and flow configurations and as such, provides an additional step toward understanding the detailed fluid mechanical behavior of the more complex physiological configurations seen clinically.
Publisher
ASME International
Subject
Physiology (medical),Biomedical Engineering
Reference36 articles.
1. Fontan, F., and Baudet, E., 1971, “Surgical Repair of Tricuspid Artesia,” Thorax, 26, pp. 240–248. 2. de Leval, M. R. , 1998, “The Fontan Circulation,” Pediatr. Cardiol., 19, pp. 316–320. 3. de Leval, M. R., Kilner, P., Gewillig, M., and Bull, C., 1988, “Total Cavopulmonary Connection: A Logical Alternative to Atriopulmonary Connection for Complex Fontan Operations,” J. Thorac. Cardiovasc. Surg., 96, pp. 682–695. 4. Sharma, S., Goudy, S., Walker, P., Panchal, S., Ensley, A., Kanter, K., Tam, V., Fyfe, D., and Yoganathan, A. P., 1996, “In Vitro Flow Experiments for Determination of Optimal Geometry of Total Cavopulmonary Connection for Surgical Repair of Children with Functional Single Ventricle,” J. Am. Coll. Cardiol., 27, pp. 1264–1269. 5. Kim, Y. H., Walker, P. G., Fontaine, A. A., Panchal, S., Ensley, A. E., Oshinski, J., Sharma, S., Ha, B., Lucas, C. L., and Yoganathan, A. P., 1995, “Hemodynamics of the Fontan Connection: An In-Vitro Study,” J. Biomech. Eng., 117, pp. 423–428.
Cited by
49 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|