Heat transfer enhancement in a thermal storage system consisting of vertically arranged fins between a heated and cooled horizontal finned-tube arrangement is reported. The high thermal expansion coefficient and low viscosity of paraffin wax, at temperatures above 50°C, are utilized to induce natural convection in the liquid phase even at small thicknesses. The experimental data on the rate of production of liquid as a function of time and temperature of the hot surface is presented. The photographs of the melted zone indicate a naturally buoyant flow induced in the neighborhood of the vertical fins causes a rapid melting of the solid wax and a downdraft along the cooler solid phase surface. The heat transfer coefficient at the interface is calculated from experimentally determined instantaneous locations of the moving boundary.