Biomechanical Measurements of Torsion-Tension Coupling in Human Cadaveric Femurs

Author:

Zdero Rad1,McConnell Alison J.2,Peskun Christopher3,Syed Khalid A.4,Schemitsch Emil H.5

Affiliation:

1. Martin Orthopaedic Biomechanics Laboratory, Shuter Wing (Room 5-066), St. Michael’s Hospital, 30 Bond Street, Toronto, ON, M5B 1W8, Canada; Department of Mechanical and Industrial Engineering, Ryerson University, Toronto, ON, M5B 2K3, Canada

2. Medtronic International Trading Sàrl, Tolochenaz CH-1131, Switzerland

3. Department of Surgery, Faculty of Medicine, University of Toronto, Toronto, ON, M5S 1A8, Canada

4. Division of Orthopaedic Surgery, Toronto Western Hospital, Toronto, ON, M5T 2S8, Canada

5. Martin Orthopaedic Biomechanics Laboratory, St. Michael’s Hospital, Toronto, ON, M5B 1W8, Canada; Department of Surgery, Faculty of Medicine, University of Toronto, Toronto, ON, M5S 1A8, Canada

Abstract

The mechanical behavior of human femurs has been described in the literature with regard to torsion and tension but only as independent measurements. However, in this study, human femurs were subjected to torsion to determine if a simultaneous axial tensile load was generated. Fresh frozen human femurs (n=25) were harvested and stripped of soft tissue. Each femur was mounted rigidly in a specially designed test jig and remained at a fixed axial length during all experiments. Femurs were subjected to external and internal rotation applied at a constant angulation rate of 0.1 deg/s to a maximum torque of 12 N m. Applied torque and generated axial tension were monitored simultaneously. Outcome measurements were extracted from torsion-versus-tension graphs. There was a strong relationship between applied torsion and the resulting tension for external rotation tests (torsion/tension ratio=551.7±283.8 mm, R2=0.83±0.20, n=25), internal rotation tests (torsion/tension ratio=495.3±233.1 mm, R2=0.87±0.17, n=24), left femurs (torsion/tension ratio=542.2±262.4 mm, R2=0.88±0.13, n=24), and right femurs (torsion/tension ratio=506.7±260.0 mm, R2=0.82±0.22, n=25). No statistically significant differences were found for external versus internal rotation groups or for left versus right femurs when comparing torsion/tension ratios (p=0.85) or R2 values (p=0.54). A strongly coupled linear relationship between torsion and tension for human femurs was exhibited. This suggests an interplay between these two factors during activities of daily living and injury processes.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Reference30 articles.

1. DeFrances, C. J., Lucas, C. A., Buie, V. C., and Golosinskiy, A., 2008, “2006 National Hospital Discharge Survey,” National Health Statistics Report No. 5, pp. 1–20.

2. U.S. Department of Transportation, 2007, Transportation Statistics Annual Report 2007, Washington, DC, available from http://www.bts.gov

3. Fracture and Dislocation Classification Compendium—2007: Orthopaedic Trauma Association Classification, Database and Outcomes Committee;Marsh;J. Orthop. Trauma

4. The Biomechanics of Human Femurs in Axial and Torsional Loading: Comparison of Finite Element Analysis, Human Cadaveric Femurs, and Synthetic Femurs;Papini;ASME J. Biomech. Eng.

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献