Affiliation:
1. Department of Mechanical Engineering, University of Nottingham, Nottingham, NG7 2RD U.K.
Abstract
The film cooling effectiveness provided by two rows of holes separated by a range of distances has been studied experimentally using a mass transfer technique. The blowing rates at the two rows were varied independently. The results are presented in forms suitable for design purposes. Spanwise and area averaged effectivenesses are given for a range of blowing rates. Thus optimum blowing rates for a given row spacing and total coolant flow can be established. Comparisons with a simple superposition theory show that this can be used with safety for design purposes if the holes in the two rows are staggered, but restrictions apply if they are in-line.
Cited by
13 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献