Affiliation:
1. Rheology Laboratory, Department of Mechanical Engineering, Universidade Federal do Espírito Santo, Vitória, Espírito Santo 29075-910, Brazil
2. LEMC, Department of Physiological Sciences, Universidade Federal do Espírito Santo, Vitória, Espírito Santo 29040-090, Brazil
3. Fluid Mechanics Research Laboratory, Department Mechanical Engineering, Instituto Federal do Espírito Santo, São Mateus, Espírito Santo 29932-540, Brazil
Abstract
Abstract
Drag reduction (DR) by polymers has several industrial applications, and it has also shown to produce beneficial effects on blood circulation and may represent a way to treat cardiovascular disorders. Concerning medical applications, there are basically two types of studies using drag reducing polymers (DRP), i.e., in vitro and in vivo. Although blood may be used in the in vitro studies, there are several limitations, such as incompatibility of Rh and possibility of denaturing blood proteins. Thus, biomedical researchers commonly use an artificial plasma-like saline nutrient solution (SNS), which contains ions, nutrients, a buffer to maintain pH levels and a supply of oxygen to the tissue. The behavior of the DRP in water is well reported in the literature, but the SNS components can interact with the polymers, changing their capacity to reduce drag. This study investigates the behavior of three different polymers, i.e., polyacrylamide (PAM), polyethylene oxide (PEO), and xanthan gum (XG), when applied as DRP to a commonly used SNS. For the conditions evaluated, the SNS composition does not change significantly PAM and PEO behavior, showing that they can be satisfactorily diluted in this solvent without loss of efficiency as drag reducers. However, it modifies XG conformation, drastically reducing its efficiency. The experiments with tail arterial beds suggest that PAM is efficient to reduce the perfusion pressure, but PEO and XG do not seem to be good reducers under the experimental conditions that have been analyzed, possibly due to the interaction of the drag reducers with the flow, with the solvent components and with the tissues that were kept alive during the experiments. Although PEO did not present a good performance as DRP for the conditions evaluated in the perfusion tests, its performance can be improved in other organs where the turbulence levels, or instabilities, are higher, as suggested by the rheometer tests.
Reference37 articles.
1. Studies of Drag Reduction Conducted Over a Broad Range of Pipeline Conditions When Flowing Prudhoe Bay Crude Oil;J. Rheol.,1980
2. New Generation Drag Reducer,1995
3. The Effect of Grafted and Ungrafted Guar Gum on Turbulent Flow of Water and on Hydraulic Conductivity of Soil,1985
4. Suppression of Atherosclerosis in Rabbits Using Drag Reducing Polymers;Biorheology,1978
5. Effects of Drag Reducing Polymers on Initiation of Atherosclerosis;Polym. Eng. Sci.,1980
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献