Combined Pinch and Exergy Evaluation for Fault Analysis in a Steam Power Plant Heat Exchanger Network

Author:

Njoku Howard O.12,Egbuhuzor Linus C.3,Eke Mkpamdi N.4,Enibe Samuel O.5,Akinlabi Esther A.6

Affiliation:

1. Applied Renewable and Sustainable Energy Research Group, Department of Mechanical Engineering, University of Nigeria, Nsukka 410001, Nigeria;

2. Department of Mechanical Engineering Science, University of Johannesburg, Johannesburg 2006, South Africa e-mails: ;

3. Egbin Power PLC, Ijede, Lagos State, Nigeria e-mail:

4. Department of Mechanical Engineering, University of Nigeria, Nsukka 410001, Nigeria e-mail:

5. Professor Department of Mechanical Engineering, University of Nigeria, Nsukka 410001, Nigeria e-mail:

6. Professor Department of Mechanical Engineering Science, University of Johannesburg, Johannesburg 2006, South Africa e-mail:

Abstract

This study demonstrates comparative applications of the standard pinch and exergy analysis and the combined pinch-exergy analysis methodologies to a gas-fired steam power plant’s heat exchanger network. The extent to which each methodology could be used for pin-pointing the location of performance deteriorations in the network and their relative criticality were shown. Using a 12 °C minimum temperature difference, the network minimum hot utility requirement in current operation was determined by a pinch analysis as 539,491 kW, at a supply temperature of 549 °C. This represented a 6% (30,618 kW) increase in the utility requirement when compared with the design minimum requirement (508,873.7 kW). The combined exergy pinch analysis showed the severity of performance deteriorations more clearly, determining a 25% increase in global plant exergy losses with respect to design conditions. With a standard exergy analysis, additional information on the actual network components responsible for the changes was obtained—there were general declines in component performances except for two heaters and the deaerator, whose operation performances improved slightly. Furthermore, avoidable and inevitable exergy losses (Ξ˙d,AVO and Ξ˙d,INE, respectively) were determined for network components. Whereas both were highest for the boiler, the values of the ratio Ξ˙d,AVO/Ξ˙d,INE showed that higher potentials for performance improvement existed in the other network components. This indicates the ratio Ξ˙d,AVO/Ξ˙d,INE as an appropriate measure for deciding equipment in the heat exchanger network that are in need critical attention.

Publisher

ASME International

Subject

Geochemistry and Petrology,Mechanical Engineering,Energy Engineering and Power Technology,Fuel Technology,Renewable Energy, Sustainability and the Environment

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3