Affiliation:
1. Energy Conversion and Renewable Energy Group, School of Mechanical and Automotive Engineering, RMIT University, Melbourne 3083, VIC, Australia
Abstract
Abstract
Humidification–dehumidification (HDH) desalination with direct contact dehumidifier system is designed and fabricated. Experimental tests are performed under various operating conditions in order to explore the influence of temperatures and mass flow rates of seawater and freshwater on system performance by utilizing non-dimensional parameters. It is shown that, for any case, there is an optimum flow rate ratio of water to air, which results in a maximum water production rate. A mathematical model is utilized to evaluate the system performance and compare the outcomes with the experimental results. In addition, the effect of feed water salinity from 0–30% on the water production rate is experimentally investigated. The results showed that the maximum achieved recovery ratio of the proposed HDH system is 5% under the working condition of seawater temperature at 73 °C with 3% salinity and cold freshwater at 28 °C. Furthermore, the system was able to produce water at nearly saturated seawater feed.
Subject
Geochemistry and Petrology,Mechanical Engineering,Energy Engineering and Power Technology,Fuel Technology,Renewable Energy, Sustainability and the Environment
Cited by
12 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献