Evolution of a Novel Intraductal Patent Ductus Arteriosus Occlusion Device

Author:

Agrawal Megha,Sonetha Vaibhavi A.,Sharma Smriti,Parakh Satyajeet1,Dalvi Bharat2,Bellare Jayesh R.1

Affiliation:

1. Department of Chemical Engineering, Indian Institute of Technology Bombay, Powai, Mumbai 400076, India

2. Consultant Cardiologist Glenmark Cardiac Centre, 10 Nandadeep, 209 D, Doctor Ambedkar Road, Matunga (E), Mumbai 400019, India

Abstract

Persistence of the ductus arteriosus (DA) after birth leads to the congenital heart disease known as patent ductus arteriosus (PDA). The objective of this study is to develop an evaluation protocol and to propose a new and innovative intraductal design for a PDA occluder in order to conform to the varied morphology of the DA and to overcome the problems associated with devices relying on the anchorage mechanism. The new design, an assembly of 36 planar thermally treated Nitinol wires called Novel Device 36 (ND36), is in the shape of a frustum of a cone with a larger diameter of 12 mm, smaller diameter of 6 mm, and length of 11 mm. In-vitro biomimetic evaluations, namely, hemolysis tests and platelet adhesion studies, were conducted to ascertain the biocompatibility of the thermally treated Nitinol wires. These tests were also conducted on two different dimensions of Dacron fibers, which were to be sutured onto the device to induce thrombogenesis while in the duct, thereby facilitating better occlusion. Flow dynamics tests, which help simulate the dynamic conditions prevalent in the duct, were carried out on the ND36 and a commercially used PDA occlusion device. An analysis of the scanning electronic microscopy images showed no platelet adhesion on the Nitinol wires. The tested wires also showed nearly 0% hemolysis. Dacron fibers 0.2 mm thick and having an area density of 77 GSM proved to be best suited. Comparative analysis carried out with the commercially available Amplatzer duct occluder during the flow dynamics tests showed that the ND36 was capable of effectively occluding the duct as well as remaining stable under the dynamic conditions encountered in the duct. The ND36 has the potential to efficiently serve as a simplistic and cost effective alternative for PDA occlusion.

Publisher

ASME International

Subject

Biomedical Engineering,Medicine (miscellaneous)

Reference13 articles.

1. Congenital Heart Disease in India: A Status Report;Saxena;Indian J. Pediatr.

2. Device Closure of Patent Ductus Arteriosus;Arora;J. Interv. Cardiol.

3. Interventional Pediatric Cardiology: Transcatheter Closure of Patent Ductus Arteriosus in Chinese Adults: Immediate and Long-Term Results;Lee;The Journal of Invasive Cardiology.

4. Nonsurgical Closure of Patent Ductus Arteriosus: Clinical Application of the Rashkind PDA Occluder System;Rashkind;Congenital Heart Disease

5. Closure of a Persistent Ductus Arteriosus Without Thoracotomy;Porstmann;Ger. Med. Mon.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3