Measurements of Temperature and Emissivity Distributions on a High-Temperature Surface Using an Auxiliary Light Source Method

Author:

Fu Tairan1,Xiong Yehan2,Liu Jiangfan2,Shi Congling3

Affiliation:

1. Key Laboratory for Thermal Science and Power Engineering of Ministry of Education, Beijing Key Laboratory of CO2 Utilization and Reduction Technology, Department of Thermal Engineering, Tsinghua University, Beijing 100084, China e-mail:

2. Key Laboratory for Thermal Science and Power Engineering of Ministry of Education, Beijing Key Laboratory of CO2 Utilization and Reduction Technology, Department of Thermal Engineering, Tsinghua University, Beijing 100084, China

3. China Academy of Safety Science and Technology, Beijing 100029, China e-mail:

Abstract

A method to simultaneously measure two-dimensional temperature and emissivity distributions on high-temperature diffuse surfaces is developed using an auxiliary light source. The high-temperature diffuse surface is irradiated from the hemispherical space with the auxiliary light source switched “on” or “off.” Two images of the effective radiation intensity are obtained in quick succession for the two states to determine the temperature and emissivity distributions. The measurement method and uncertainty models show that the effect of the unknown emissivity on the accuracy of the temperature field measurement can be eliminated. The optical pyrometer is a color charge coupled device (CCD) sensor with a quartz lamp array used as the auxiliary light source to illustrate the measurement method. An oxidized W–Ni–Fe alloy sample is heated at high temperatures of 600–1000 °C by a 700 W induction-heating device. The distributions of the effective radiation intensities from the sample surface during the “on” and “off” states of the lamp array are measured in the three color channels (R, G, and B channels) to calculate the temperature and emissivity distributions. The temperature measurement uncertainties are less than 4 °C for a temperature range of 600–900 °C. The temperature measurements are experimentally validated by the thermocouple method only with a small temperature difference. The emissivities calculated from the three color channels are very close with a range of 0.855–0.957. The relative uncertainties in the emissivities for channels R and G are less than 2.0%, while the relative uncertainty for channel B data was higher at 2.8% and 7.5% due to lower measurement signals in channel B. This analysis may provide a useful method for measuring the temperatures of high-temperature diffuse surfaces by successfully compensating for the effects of unknown or changing emissivities.

Publisher

ASME International

Subject

Mechanical Engineering,Mechanics of Materials,Condensed Matter Physics,General Materials Science

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3