Optimization of Thermal Mass in Commercial Building Applications

Author:

Brown M. Judson1

Affiliation:

1. The Fleming Group, East Syracuse, NY 13057

Abstract

Based on results from a one-year intensive monitoring project of a Northern New York commercial building with energy-conserving design features, a thermal storage project was undertaken to optimize the design of a thermal mass storage system for a moderately sized commercial building and transfer the technology to the commercial building sector. A generic commercial building design of 27,000 square feet (2508 m2) was selected for the optimization project. Several different types of thermal mass designs were considered as potentially practical for a commercial building. These included a “sandmass” design such as the mass incorporated in the previously monitored commercial building mentioned above, a foundation slab of sufficient thickness to serve as a significant building thermal mass, and the use of poured cement in interior wall and floor construction. Five different office building thermal designs were selected which represented various thermal storage features and two different building insulation levels (R10 and R20). Energy performance of the five thermal designs was modeled in building energy simulations using DOE 2.1C (Department of Energy 2.1C) energy simulation code. Results of the simulations showed a reduction in peak heating and cooling loads would be experienced by the HVAC equipment. The reduction in peak heating and cooling loads was anticipated because thermal mass within a building serves to average peak heating and cooling loads due to the capacity of the thermal mass to store and release heat from all building heat sources over a period of time. Peak heating loads varied from 1972 kBtuh (578 kW) for the R-10 light construction base case to a minimum of 980 kBtuh (287 kW) for the R-20 heavy construction sandmass storage case. Peak cooling loads dropped from 772 kBtuh (226 kW) for the R-20 light construction case to 588 kBtuh (172 kW) for the R-20 heavy construction sandmass storage case. Results of the simulations also showed annual energy savings for the high thermal mass designs. Energy savings varied from 20 percent [16.0 kBtu/ft2 (50 kWh/m2)] for the R-10 high thermal mass design in comparison to its base case to 18 percent [12.2 kBtu/ft2 (39 kWh/m2)] for the R-20 high thermal mass design in comparison to its base case. The annual energy savings are due to the ability of the thermal mass to absorb heat from all sources of heat generation (lights, occupancy, solar, and auxiliary) during occupied periods and release the heat during unoccupied periods. An optimized thermal design was developed based on results from the DOE 2.1C simulations. The initial cost for the optimized thermal storage design is lower than the initial costs for light construction office buildings, since the lower initial cost of the down-sized HVAC system for the optimized thermal storage design more than offsets the increased cost of wall and floor systems incorporated in the optimized design. Annual energy savings are realized from the high thermal mass system in both cooling and heating modes due to the interaction of building HVAC systems operation in the simulated 27000 ft2 (2508 m2) office building. Annual operating savings of $3781 to $4465 per year are estimated based on simulation results.

Publisher

ASME International

Subject

Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment

Cited by 18 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3