A Comparison of the Temperature Rise Generated in Bone by the Use of a Standard Oscillating Saw Blade and the “Precision” Saw Blade

Author:

Lustig Sebastien1,Scholes Corey J.,Oussedik Sam2,Tam Sam3,Dabirrahmani Danè,Appleyard Richard4,Parker David A.2

Affiliation:

1. Sydney Orthopaedic Research Institute, Chatswood, NSW, 2046 Australia; Albert Trillat Center, Lyon University Hospital, Lyon 1, France e-mail:

2. Sydney Orthopaedic Research Institute, Chatswood, NSW 2046, Australia

3. Sydney Orthopaedic Research Institute, Chatswood, NSW, 2046 Australia; School of Aerospace, Mechanical and Mechatronic Engineering, University of Sydney, NSW 2006, Australia

4. Australian School of Advanced Medicine, Macquarie University, NSW 2109, Australia

Abstract

Introduction. Osteonecrosis may be triggered by bone temperatures above 47 °C during routine orthopaedic bone cuts using power-driven saws with potentially negative impacts on bone healing. A new oscillating-tip saw blade design (Precision®; Stryker, Kalamazoo, USA) has been recently developed with a saw blade design that may influence the amount of heat generated. We have, therefore, sought to compare the bone temperature achieved using this new blade design with a standard oscillating saw during a standardized cutting task. Method. Six human cadaveric femora were obtained. Each femur was clamped and a distal femoral cutting jig was applied. An initial cut was performed to visualize the distal metaphyseal bone. The cutting block was then moved 2 mm proximal and a further cut performed, measuring the temperature of the bone with an infrared camera. This was repeated, moving the block 2 mm proximal with each cut, alternating between a standard oscillating saw blade (12 cuts) and the Precision® saw blade (12 cuts). The bone density at the level of each slice was established from a CT scan of each specimen which had been performed prior to the experiment. Results. The two blades did not differ with respect to the integrated mean temperature calculated for each cut (p = 0.89). The average peak temperatures were not significantly different between blades (p = 0.14). There was no significant difference between blades for peak heating rate (p = 0.7), although the area of bone heated above the 47 deg osteonecrotic threshold was significantly (p = 0.04) less for the standard saw blade. Conclusions. The Precision® blade may have advantages over standard oscillating blade, but reduced heat generation was not observed in this study. Indeed, the Precision® blade generated heat that exceeded the bony osteonecrosis threshold in a greater proportion of bone than the standard blade, questioning its use for osteotomy or uncemented knee arthroplasty. Further work should examine modifications to the blade design to better optimize the requirements of speed, accuracy and heat generation.

Publisher

ASME International

Subject

Biomedical Engineering,Medicine (miscellaneous)

Reference26 articles.

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3