Changes in Shear Modulus of the Lumbar Multifidus Muscle During Different Body Positions

Author:

Sadeghi Seyedali1,Quinlan Kevin2,Eilertson Kirsten E.2,Billy Gregory G.3,Bible Jesse3,Sions Jaclyn Megan4,Cortes Daniel H.5

Affiliation:

1. Department of Mechanical and Nuclear Engineering, College of Engineering, The Pennsylvania State University, State College, PA 16802 e-mail:

2. Department of Statistics, The Pennsylvania State University, State College, PA 16802 e-mail:

3. The Milton S. Hershey Medical Center, Department of Surgery, Hershey, PA 17033 e-mail:

4. Department of Physical Therapy, University of Delaware, Newark, DE 19713 e-mail:

5. Department of Mechanical and Nuclear Engineering, College of Engineering, The Pennsylvania State University, State College, PA 16802; Department of Biomedical Engineering, College of Engineering, The Pennsylvania State University, State College, PA 16802 e-mail:

Abstract

Multifidus function is important for active stabilization of the spine, but it can be compromised in patients with chronic low back pain and other spine pathologies. Force production and strength of back muscles are often evaluated using isometric or isokinetic tests, which lack the ability to quantify multifidi contribution independent of the erector spinae and adjacent hip musculature. The objective of this study is to evaluate localized force production capability in multifidus muscle using ultrasound shear wave elastography (SWE) in healthy individuals. Three different body positions were considered: lying prone, sitting up, and sitting up with the right arm lifted. These positions were chosen to progressively increase multifidus contraction and to minimize body motion during measurements. Shear modulus was measured at the superficial and deeper layers of the multifidus. Repeatability and possible sources of error of the shear modulus measurements were analyzed. Multifidus shear modulus (median (interquartile range)) increased from prone, i.e., 16.15 (6.69) kPa, to sitting up, i.e., 27.28 (15.72) kPa, to sitting up with the right arm lifted position, i.e., 45.02 (25.27) kPa. Multifidi shear modulus in the deeper layer of the multifidi was lower than the superficial layer, suggesting lower muscle contraction. Intraclass correlation coefficients (ICCs) for evaluation of shear modulus by muscle layer were found to be excellent (ICC = 0.76–0.80). Results suggest that the proposed protocol could quantify local changes in spinal muscle function in healthy adults; further research in patients with spine pathology is warranted.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3