Introduction to Force-Dependent Kinematics: Theory and Application to Mandible Modeling

Author:

Skipper Andersen Michael1,de Zee Mark2,Damsgaard Michael3,Nolte Daniel4,Rasmussen John1

Affiliation:

1. Department of Materials and Production, Aalborg University, Fibigerstraede 16, Aalborg East, Aalborg DK-9220, Denmark e-mail:

2. Department of Health Science and Technology, Aalborg University, Fredrik Bajers Vej 7, Aalborg East, Aalborg DK-9220, Denmark e-mail:

3. AnyBody Technology A/S, Niels Jernes Vej 10, Aalborg East, Aalborg DK-9220, Denmark e-mail:

4. Department of Bioengineering, Imperial College London, London SW7 2AZ, UK e-mail:

Abstract

Knowledge of the muscle, ligament, and joint forces is important when planning orthopedic surgeries. Since these quantities cannot be measured in vivo under normal circumstances, the best alternative is to estimate them using musculoskeletal models. These models typically assume idealized joints, which are sufficient for general investigations but insufficient if the joint in focus is far from an idealized joint. The purpose of this study was to provide the mathematical details of a novel musculoskeletal modeling approach, called force-dependent kinematics (FDK), capable of simultaneously computing muscle, ligament, and joint forces as well as internal joint displacements governed by contact surfaces and ligament structures. The method was implemented into the anybody modeling system and used to develop a subject-specific mandible model, which was compared to a point-on-plane (POP) model and validated against joint kinematics measured with a custom-built brace during unloaded emulated chewing, open and close, and protrusion movements. Generally, both joint models estimated the joint kinematics well with the POP model performing slightly better (root-mean-square-deviation (RMSD) of less than 0.75 mm for the POP model and 1.7 mm for the FDK model). However, substantial differences were observed when comparing the estimated joint forces (RMSD up to 24.7 N), demonstrating the dependency on the joint model. Although the presented mandible model still contains room for improvements, this study shows the capabilities of the FDK methodology for creating joint models that take the geometry and joint elasticity into account.

Funder

Højteknologifonden

Det Frie Forskningsråd

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Reference35 articles.

1. Individual Motion Patterns During Gait and Sit-to-Stand Contribute to Edge-Loading Risk in Metal-on-Metal Hip Resurfacing;Proc. Inst. Mech. Eng., Part H,2013

2. Computational Analysis of the Influence of Seat Pan Inclination and Friction on Muscle Activity and Spinal Joint Forces;Int. J. Ind. Ergon.,2009

3. Validation of a Musculoskeletal Model of Lifting and Its Application for Biomechanical Evaluation of Lifting Techniques;J. Res. Health Sci.,2014

4. Use of Optimization Techniques to Predict Muscle Forces;ASME J. Biomech. Eng.,1978

5. Muscle Recruitment by the Min/Max Criterion: A Comparative Numerical Study;J. Biomech.,2001

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3