Effect of Annular Incision Type on the Change in Biomechanical
Properties in a Herniated Lumbar Intervertebral Disc
Author:
Natarajan R. N.1, Andersson G. B. J.1, Patwardhan A. G.2, Verma S.3
Affiliation:
1. Department of Orthopedic Surgery, Rush-Presbyterian-St. Luke’s Medical Center, 1653 West Congress Parkway, Chicago, IL 60612 2. Department of Orthopaedic Surgery, Loyola University Medical Center, Maywood, IL 60606 3. Department of Mechanical Engineering, Illinois Institute Of Technology, Chicago, IL 60616
Abstract
Abstract
The technique used to incise the disc during discectomy may play a role in the subsequent healing and change in biomechanical stiffness of the disc. Several techniques of lumbar disc annulotomy have been described in clinical reports. The purpose of this paper was to study the influence of annulotomy technique on motion segment stiffness using a finite element model. Four incision methods (square, circular, cross, and slit) were compared. The analyses showed that each of the annular incisions produced increase in motions under axial moment loadings with circular incision producing the largest change in the corresponding rotational motion. Under shear loading mode, cross and slit-type annular incisions produced slightly larger changes in the principal motions of the disc than square and circular incisions. All other incision types considered in the current study produced negligibly small increase in motion under rest of the loading conditions. In addition to annulotomy, when nucleotomy was also included in the analyses, once again cross and slit incisions produced larger change in motion under shear loading mode as compared to the other two incision types. A comparison between the four types of annular incisions showed that cross incision produced an increase in motion larger than those produced by the other three incisions under flexion/extension and lateral moment loading and both shear force loadings. Circular incision produced the largest increase in motion under axial moment load in comparison to those produced by square, cross, and slit incisions. Sagittal plane symmetry was influenced by the incision injury to the motion segment leading to coupled motions as well as increased facet loads. From the study it can be concluded that the increase in flexibility of the disc due to annulotomy depends on the type of annulotomy, and the annulotomy also produce asymmetrical deformations leading to increased facet loading.
Publisher
ASME International
Subject
Physiology (medical),Biomedical Engineering
Reference16 articles.
1. Brinckmann,
P., and
Horst,
M.,
1985, “The Influence of Vertebral Body
Fracture, Intradiscal Injection and Partial Discectomy on the Radial Bulge
and Height of Human Lumbar Discs,” Spine
, 10, pp.
138–145. 2. Brinckmann,
P.
,
1986, “Injury of the Annulus Fibrosus and
Disc Protrusions—An In Vitro Investigation on Human Lumbar
Discs,” Spine , 11,
pp. 149–153. 3. Seroussi,
R.,
Krag,
M.,
Muller,
D., and
Pope,
M.,
1989, “Internal Deformations of Intact
and Denucleated Human Lumbar Discs Subjected to Compression, Flexion and
Extension Loads,” J. Orthop. Res.,
l7, pp.
122–131. 4. Shia,
M.,
Takeuchi, T.
Y.,
Wittenberg, R.
H.,
White, A.
A., and
Hayes, W.
C., 1994,
“A Comparison of the Effects of Automated Percutaneous
Diskectomy and Conventional Diskectomy on Intradiscal Pressure, Disk
Geometry, and Stiffness,” J. Spinal
Disord., 17, pp.
317–325. 5. Panjabi, M.
M.,
Krag, M.
H., and
Chung, T.
Q., 1984,
“Effects of Disc Injury on Mechanical Behavior of the
Human Spine,” Spine ,
9, pp.
707–713.
Cited by
16 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|