Modeling and Optimal Control of a Variable-Speed Centrifugal Pump With a Pipeline

Author:

Jaimes Saavedra Cristian F.1,Roa Prada Sebastian1,Maradey Lázaro Jessica G.1

Affiliation:

1. Universidad Autónoma de Bucaramanga, Bucaramanga, Colombia

Abstract

Pumping processes often require different operating conditions for the same pipeline. The conditions downstream in the pipeline can change in such a way that the pressure at the discharge of the pump may vary, which automatically introduces changes in the flow supplied by the pump into the pipeline due to the head vs flow characteristic curve of the pump. Even under varying pipeline pressure conditions, it may be necessary to keep the flow discharge of the pump constant. The two most commonly used control strategies for flow control with centrifugal pumps are by means of a fixed-speed pump and a control valve at the outlet of the pump, or by means of a variable frequency drive which avoids the need for the control valve. It has been demonstrated that the approach with the fixed-speed pump and the control valve provides poor power efficiency results, so a variable frequency drive is normally the solution of choice in industry applications. The use of a variable frequency drive allows reaching the flow required by the system without changing the physical characteristic of the pump or pipeline, i.e., it is not necessary to shut the system down to replace the impeller of the pump. However, affinity laws of centrifugal pumps dictate that a change in the rotational speed of the impeller shifts the characteristic curves of the pump, not only the flow vs head curve, but also the efficiency curves, among others. Besides, searching for a different operating point by changing the speed of the pump does not necessarily guarantees optimal operating power efficiency. This paper proposes an optimization approach where a compromise is made between flow control and power efficiency by minimizing the error in the flow rate while at the same time maximizing the power efficiency. To accomplish this goal, this paper presents the modeling of the pump and pipeline, and the design of a linear quadratic regulator control for the fluid flow passing through a given pipeline. The fluid under consideration is water. The mathematical model of the overall system is derived by considering the model of an AC motor, the pump and the hydraulic circuit. Then, with the help of the software MATLAB, the controller was designed and implemented with the linearized mathematical model. The actuator of the control system is the variable frequency drive that changes the speed of the impeller to adjust the flow rate to the required operating point under different loading conditions. The results show the behavior of the compensated system with the optimal controller. In practice, the control system must take into account the constraints of the control effort, which means, the frequency of the pump must be kept within safe values to achieve proper functioning of the pumping system.

Publisher

American Society of Mechanical Engineers

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3