Activity and Loading Influence the Predicted Bone Remodeling Around Cemented Hip Replacements

Author:

Dickinson Alexander S.1

Affiliation:

1. Bioengineering Science Research Group, University of Southampton, Highfield, Southampton SO17 1BJ, UK e-mail:

Abstract

Periprosthetic bone remodeling is frequently observed after total hip replacement. Reduced bone density increases the implant and bone fracture risk, and a gross loss of bone density challenges fixation in subsequent revision surgery. Computational approaches allow bone remodeling to be predicted in agreement with the general clinical observations of proximal resorption and distal hypertrophy. However, these models do not reproduce other clinically observed bone density trends, including faster stabilizing mid-stem density losses, and loss-recovery trends around the distal stem. These may resemble trends in postoperative joint loading and activity, during recovery and rehabilitation, but the established remodeling prediction approach is often used with identical pre- and postoperative load and activity assumptions. Therefore, this study aimed to evaluate the influence of pre- to postoperative changes in activity and loading upon the predicted progression of remodeling. A strain-adaptive finite element model of a femur implanted with a cemented Charnley stem was generated, to predict 60 months of periprosthetic remodeling. A control set of model input data assumed identical pre- and postoperative loading and activity, and was compared to the results obtained from another set of inputs with three varying activity and load profiles. These represented activity changes during rehabilitation for weak, intermediate and strong recoveries, and pre- to postoperative joint force changes due to hip center translation and the use of walking aids. Predicted temporal bone density change trends were analyzed, and absolute bone density changes and the time to homeostasis were inspected, alongside virtual X-rays. The predicted periprosthetic bone density changes obtained using modified loading inputs demonstrated closer agreement with clinical measurements than the control. The modified inputs also predicted the clinically observed temporal density change trends, but still under-estimated density loss during the first three postoperative months. This suggests that other mechanobiological factors have an influence, including the repair of surgical micro-fractures, thermal damage and vascular interruption. This study demonstrates the importance of accounting for pre- to postoperative changes in joint loading and patient activity when predicting periprosthetic bone remodeling. The study's main weakness is the use of an individual patient model; computational expense is a limitation of all previously reported iterative remodeling analysis studies. However, this model showed sufficient computational efficiency for application in probabilistic analysis, and is an easily implemented modification of a well-established technique.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3