Affiliation:
1. EDF Energy Nuclear Generation Limited, Barnett Way, Barnwood, Gloucester GL4 3RS, UK
Abstract
Abstract
In R6, the J-based failure assessment diagram (FAD) method is used in the fracture assessment and is underpinned by the reference stress J scheme. Therefore, an assessment using the R6 FAD method is equivalent to a J prediction using the reference stress method. In this paper, the effect of global and local limit load solutions for defective elbows on the reference stress and hence the J predictions is investigated using published three-dimensional elastic-plastic finite element (FE) J results, in order to create guidance for users to follow when performing structural integrity assessments of defective elbows using the R6 procedure. The results show that using the global limit load solutions recommended in this paper can lead to good and reasonably conservative J predictions. However, the availability of global limit load solutions is very limited. The results also show that using the local limit load evaluated from the local limit load model recommended in this paper can lead to conservative J predictions for most of the cases considered.
Subject
Mechanical Engineering,Mechanics of Materials,Safety, Risk, Reliability and Quality
Reference14 articles.
1. The Assessment of Defects in Structures of Strain Hardening Material;Eng. Fract. Mech.,1984
2. Stress Intensity Factor Estimation for Defective Pipe Elbows,2017
3. Review of Limit Load Solutions for Defective Pipe Bends,2011
4. A Local Limit Load Model for J Prediction Via the Reference Stress Method;Struct. Integrity Procedia,2018
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献