Author:
Fleischer Friedrich,Koerner Christian,Mann Juergen
Abstract
Following repeated cases of damage caused to exhaust silencers located directly beyond gas turbine diffusers, this paper reports on investigations carried out to determine possible remedies.
In all instances, an uneven exhaust gas flow distribution was found to be present.
The company’s innovative approach to the problem involved constructing a scale model of a complete gas turbine exhaust system and using it for flow simulation purposes. It was established for the first time that, subject to certain conditions, the results of tests conducted on a model can be applied to the actual turbine exhaust system.
It is shown that when an unfavourable duct arrangement might produce an uneven exhaust flow, scale models are useful in the development of suitable flow-distributing devices.
Publisher
American Society of Mechanical Engineers
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献