Hemodynamics of Flow Diverters

Author:

Dholakia Ronak1,Sadasivan Chander1,Fiorella David J.1,Woo Henry H.1,Lieber Baruch B.2

Affiliation:

1. Department of Neurological Surgery, Stony Brook University Medical Center, Stony Brook, NY 11794

2. Professor Department of Neurological Surgery, Stony Brook University Medical Center, HSC T12, Room 080, 100 Nicolls Road, Stony Brook, NY 11794-8122 e-mail:

Abstract

Cerebral aneurysms are pathological focal evaginations of the arterial wall at and around the junctions of the circle of Willis. Their tenuous walls predispose aneurysms to leak or rupture leading to hemorrhagic strokes with high morbidity and mortality rates. The endovascular treatment of cerebral aneurysms currently includes the implantation of fine-mesh stents, called flow diverters, within the parent artery bearing the aneurysm. By mitigating flow velocities within the aneurysmal sac, the devices preferentially induce thrombus formation in the aneurysm within hours to days. In response to the foreign implant, an endothelialized arterial layer covers the luminal surface of the device over a period of days to months. Organization of the intraneurysmal thrombus leads to resorption and shrinkage of the aneurysm wall and contents, eventually leading to beneficial remodeling of the pathological site to a near-physiological state. The devices' primary function of reducing flow activity within aneurysms is corollary to their mesh structure. Complete specification of the device mesh structure, or alternately device permeability, necessarily involves the quantification of two variables commonly used to characterize porous media—mesh porosity and mesh pore density. We evaluated the flow alteration induced by five commercial neurovascular devices of varying porosity and pore density (stents: Neuroform, Enterprise, and LVIS; flow diverters: Pipeline and FRED) in an idealized sidewall aneurysm model. As can be expected in such a model, all devices substantially reduced intraneurysmal kinetic energy as compared to the nonstented case with the coarse-mesh stents inducing a 65–80% reduction whereas the fine-mesh flow diverters induced a near-complete flow stagnation (∼98% reduction). We also note a trend toward greater device efficacy (lower intraneurysmal flow) with decreasing device porosity and increasing device pore density. Several such flow studies have been and are being conducted in idealized as well as patient-derived geometries with the overarching goals of improving device design, facilitating treatment planning (what is the optimal device for a specific aneurysm), and predicting treatment outcome (will a specific aneurysm treated with a specific device successfully occlude over the long term). While the results are generally encouraging, there is poor standardization of study variables between different research groups, and any consensus will only be reached after standardized studies are conducted on collectively large datasets. Biochemical variables may have to be incorporated into these studies to maximize predictive values.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3