Abstract
A method is proposed to estimate the number of vibration cycles caused by frequency locked-in ice loads on a bottom fixed structure. Studies of the onset of frequency lock-in have been performed and based on that, different onset criteria are studied. It is shown in this work that most existing onset criteria significantly overestimate the vulnerability to frequency locked-in ice loads. The method described proposes a 90 % reduction in the number of vibration cycles in a winter season. The 2002–2003 winter at Norströmsgrund lighthouse is compared with the proposed method. The comparisons show that all available methods overestimate the number of vibration cycles significantly.
Publisher
American Society of Mechanical Engineers
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献