Optimizing the Porohyperelastic Response of a Layered Compliance Matched Vascular Graft to Promote Luminal Self-Cleaning

Author:

Behrangzade Ali1,Simon Bruce R.2,Wagner William R.34,Geest Jonathan P. Vande56

Affiliation:

1. Department of Bioengineering, University of Pittsburgh , Pittsburgh, PA 15219

2. Aerospace and Mechanical Engineering, Biomedical Engineering Interdisciplinary Program University of Arizona , Tucson, AZ 85721

3. Department of Surgery, McGowan Institute for Regenerative Medicine, University of Pittsburgh , Pittsburgh, PA 15219 ; , Pittsburgh, PA 15219

4. Department of Bioengineering, McGowan Institute for Regenerative Medicine, University of Pittsburgh , Pittsburgh, PA 15219 ; , Pittsburgh, PA 15219

5. Department of Bioengineering, McGowan Institute for Regenerative Medicine, Vascular Medicine Institute, University of Pittsburgh , Pittsburgh, PA 15219 ; , Pittsburgh, PA 15219

6. Department of Mechanical Engineering and Material Science, McGowan Institute for Regenerative Medicine, Vascular Medicine Institute University of Pittsburgh , Pittsburgh, PA 15219 ; , Pittsburgh, PA 15219

Abstract

Abstract Thrombosis and intimal hyperplasia have remained the major failure mechanisms of small-diameter vascular grafts used in bypass procedures. While most efforts to reduce thrombogenicity have used a biochemical surface modification approach, the use of local mechanical phenomena to aid in this goal has received somewhat less attention. In this work, the mechanical, fluid transport, and geometrical properties of a layered and porous vascular graft are optimized within a porohyperelastic finite element framework to maximize self-cleaning via luminal reversal fluid velocity (into the lumen). This is expected to repel platelets as well as inhibit the formation of and/or destabilize adsorbed protein layers thereby reducing thrombogenic potential. A particle swarm optimization algorithm was utilized to maximize luminal reversal fluid velocity while also compliance matching our graft to a target artery (rat aorta). The maximum achievable luminal reversal fluid velocity was approximately 246 μm/s without simultaneously optimizing for host compliance. Simultaneous optimization of reversal flow and compliance resulted in a luminal reversal fluid velocity of 59 μm/s. Results indicate that a thick highly permeable compressible inner layer and a thin low permeability incompressible outer layer promote intraluminal reversal fluid velocity. Future research is needed to determine the feasibility of fabricating such a layered and optimized graft and verify its ability to improve hemocompatibility.

Funder

American Heart Association

National Heart, Lung, and Blood Institute

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Reference44 articles.

1. Heart Disease and Stroke Statistics-2021 Update: A Report From the american Heart Association;Circulation,2021

2. Atherosclerosis;Nat. Rev. Dis. Primers,2019

3. Role of Prosthetic Conduits in Coronary Artery Bypass Grafting;Eur. J. Cardiothorac. Surg.,2011

4. Cold-Stored Venous Allografts in Different Preserving Solutions: A Study on Changes in Vein Wall Morphology;Scand. J. Surg.,2019

5. Biomaterials for Vascular Tissue Engineering;Regen. Med.,2010

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献