Bi-directional Mechanical Properties of the Axillary Pouch of the Glenohumeral Capsule: Implications for Modeling and Surgical Repair

Author:

Moore Susan M.1,McMahon Patrick J.1,Debski Richard E.1

Affiliation:

1. Musculoskeletal Research Center, Department of Orthopaedic Surgery, University of Pittsburgh

Abstract

The objective of this study was to determine the mechanical properties of the axillary pouch of the inferior glenohumeral ligament in the directions perpendicular (transverse) and parallel (longitudinal) to the longitudinal axis of the anterior band of the inferior glenohumeral ligament. A punch was used to excise one transverse and one longitudinal tissue sample from the axillary pouch of each cadaveric shoulder (n=10). Each tissue sample was preconditioned and then a load-to-failure test was performed. All tissue samples exhibited the typical nonlinear behavior reported for ligaments and tendons. Significant differences (p<0.05) were detected between the transverse and longitudinal tissue samples for ultimate stress (0.8±0.4 MPa and 2.0±1.0 MPa, respectively) and tangent modulus (5.4±2.9 MPa and 14.8±13.1 MPa, respectively). No significant differences (p>0.05) were observed between the ultimate strain (transverse: 23.5±11.5%, longitudinal: 33.3±23.6%) and strain energy density (transverse: 10.8±8.5 MPa, longitudinal: 21.1±15.4 MPa) of the transverse and longitudinal tissue samples. The ultimate stress determined for the longitudinal axillary pouch tissue samples was comparable to a previous study that reported it to be 5.5±2.0 MPa. The ratio of the longitudinal to transverse moduli (3.3±2.8) is considerably less than that of the medial collateral ligament of the knee (30) and interosseous ligament of the forearm (385), suggesting that the axillary pouch functions to stabilize the joint in more than just one direction. Future models of the glenohumeral joint and surgical repair procedures should consider the properties of the axillary pouch in its transverse and longitudinal directions to fully describe the behavior of the inferior glenohumeral ligament.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3