Hydrodynamic Evaluation of a Minimally Invasive Heart Valve in an Isolated Aortic Root Using a Modified In Vitro Model

Author:

Wang Qiang1,Jaramillo Fernando1,Kato Yasushi2,Pinchuk Leonard2,Schoephoerster Richard T.3

Affiliation:

1. Department of Biomedical Engineering, Florida International University, 10555 West Flagler Street, EC 2610, Miami, FL 33174

2. Innovia LLC, 12415 Southwest 136th Avenue, Miami, FL 33186

3. College of Engineering, University of Texas at El Paso, 500 West University Avenue, Engineering Building M-305, El Paso, TX 79968-0517

Abstract

Implantation methods for commercially available heart valve prostheses require open-chest access to the heart to perform the suturing process. In order to alleviate this complicated surgical implant technique, a “stent-valve” design was developed that will provide a less cumbersome implantation method and therefore a less invasive access to the heart. The purpose of this study is to verify its hydrodynamic performance and migration characteristics to assess its feasibility for use as a replacement heart valve. Hydrodynamic evaluation of the novel stent-valve combination device was carried out using a Vivitro left heart simulator and by setting up a comparison with the same 19 mm trileaflet valve under a traditional implantation (suture) method. To assess implantation ability under normal physiological conditions, porcine aortic root tissue was mounted into the left heart simulator to replace the original glass sinus. A comparison experiment was conducted to study the change in the total compliance and resistance of the testing system using the modified Windkessel model. For the range of test conditions investigated, the stent-valve combination device produced an average pressure gradient of 41.2 mm Hg(±19.6 mm Hg), an average effective orifice area (EOA) of 1.06 cm2(±0.08 cm2), and an average regurgitation percentage of 4.5% (±3.3%), while the sutured valve produced an average pressure gradient of 48.7 mm Hg(±17.4 mm Hg), an average EOA of 0.88 cm2(±0.14 cm2), and an average regurgitation percentage of 0.8% (±0.4%). The total compliance and resistance of the system was 0.37 ml/mm Hg(±0.01 ml/mm Hg) and 1.1 mm Hg/ml/s(±0.29 mm Hg/ml/s), with the original Windkessel model, and 0.33 ml/mm Hg(±0.01 ml/mm Hg) and 1.1 mm Hg/ml/s(±0.24 mm Hg/ml/s) for the system with the aortic tissue. The stent-valve combination device has demonstrated favorable hydrodynamic performance when compared with the same trileaflet valve under the traditional suturing method, and the arterial stent makes it possible to secure the valve at its required position without migration.

Publisher

ASME International

Subject

Biomedical Engineering,Medicine (miscellaneous)

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3