Methods for Post Hoc Quantitative Computed Tomography Bone Density Calibration: Phantom-Only and Regression

Author:

Reeves Jacob M.1,Knowles Nikolas K.2,Athwal George S.3,Johnson James A.1

Affiliation:

1. Department of Mechanical Engineering, Western University Canada, 1151 Richmond Street, London, ON N6A3K7, Canada e-mail:

2. Department of Biomedical Engineering, Western University Canada, 1151 Richmond Street, London, ON N6A3K7, Canada e-mail:

3. Roth|McFarlane Hand and Upper Limb Centre, 268 Grosvenor Street, London, ON N6A4V2, Canada e-mail:

Abstract

Quantitative computed tomography (qCT) relies on calibrated bone mineral density data. If a calibration phantom is absent from the CT scan, post hoc calibration becomes necessary. Scanning a calibration phantom after-the-fact and applying that calibration to uncalibrated scans has been used previously. Alternatively, the estimated density is known to vary with CT settings, suggesting that it may be possible to predict the calibration terms using CT settings. This study compares a novel CT setting regression method for post hoc calibration to standard and post hoc phantom-only calibrations. Five cadaveric upper limbs were scanned at 11 combinations of peak tube voltage and current (80–140 kV and 100–300 mA) with two calibration phantoms. Density calibrations were performed for the cadaver scans, and scans of the phantoms alone. Stepwise linear regression determined if the calibration equation terms were predictable using peak tube voltage and current. Peak tube voltage, but not current, was significantly correlated with regression calibration terms. Calibration equation slope was significantly related to the type of phantom (p < 0.001), calibration method (p = 0.026), and peak tube voltage (p < 0.001), but not current (p = 1.000). The calibration equation vertical intercept was significantly related to the type of phantom (p < 0.001), and peak tube voltage (p = 0.006), but not calibration method (p = 0.682), or current (p = 0.822). Accordingly, regression can correlate peak tube voltage with density calibration terms. Suggesting that, while standard qCT calibration is preferable, regression calibration may be an acceptable post hoc method when necessary.

Funder

Natural Sciences and Engineering Research Council of Canada

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3