A New Medical Device Modeling Framework for Predicting the Performance of Indwelling Continence Care Devices and Improving Patient Care

Author:

Bodner Jeff1,Baxter Walt2,Leung Christina2,Falkner Phillip1

Affiliation:

1. Neuromodulation Operating Unit, Medtronic, plc, Minneapolis, MN 55432

2. Neuromodulation Operating Unit, Medtronic, plc, Santa Ana, CA 92705

Abstract

Abstract A computational model of the human torso has been developed to study the stability of implanted leads that are part of a sacral nerve stimulation system. The model was built using presegmented anatomies that were themselves built from imaging of human patients. The sacral leads are represented using beam elements, and their interaction with the tissue is defined using a function that relates frictional force to the amount of slip between the lead and tissue. Displacements to the skin in the sacral region are applied to simulate activities of daily living, and the resulting displacement of the tip of the lead is indicative of its tendency to dislodge in real patients. Validation of the model was performed using experimental results collected in human cadavers. In these experiments, analogous displacements of the skin were applied after implantation of the leads per normal implant procedures. The displacement of the distal tip of the lead was measured using computed tomography (CT) imaging, allowing direct comparison to the predictions of the model. Recognizing that many model inputs were informed by sparse literature values, a novel application of uncertainty quantification methodology was developed wherein all model inputs were treated as uncertain intervals. This allowed an optimization approach to be used for estimating the uncertain interval for the model outputs. The computational model and cadaver results were used to study the performance of a new sacral lead design, relative to a predicate product. The results showed that the reduction in lead axial stiffness in the new design leads to less lead tip displacement, such that the lead is more likely to remain near the therapeutic target in patients.

Publisher

ASME International

Subject

Biomedical Engineering,Medicine (miscellaneous)

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3