The Use of Active Ionic Polymers in Dynamic Skin Friction Measurements

Author:

Etebari Ali1,Akle Barbar1,Farinholt Kevin1,Bennet Matthew1,Leo Donald J.1,Vlachos Pavlos P.1

Affiliation:

1. Virginia Polytechnic Institute and State University, Blacksburg, VA

Abstract

A class of wall shear stress sensors has been developed. The potential of ionic polymer membrane transducers for measuring skin friction in liquid flows is demonstrated. Ionic polymer transducers are thin polymer membranes that exhibit high sensitivity to mechanical strain, and have been shown to demonstrate sensitivities two orders of magnitude higher in charge-sensing mode than piezoelectric polymers such as PVDF. Thus, they are as sensitive to mechanical strain as piezoelectric ceramics (i.e. PZT) but have the high compliance and durability of a polymer. The application of active ionic polymers in delivering easy to implement, accurate, dynamic measurements of skin friction in harsh environments promises significant advantages over current technologies. In particular, a robust technique for measuring wall shear stress is needed to assess the effectiveness of new friction-reducing techniques, including the use of lubricants and micro-bubble injection within the viscous sublayer. Conventional technologies have been unable to provide sufficiently accurate measurements over a large range of fluid velocity fluctuation scales. Moreover, their implementation can be complicated in the case of non-flush mounting sensors, and their applicability is often limited to forgiving environments. An initial feasibility test was designed with the objective of replicating classic theoretical and experimental skin friction coefficient results for a sharp edge flat plate boundary layer. An ionic polymer and a piezoelectric film (PVDF) were evaluated for Reynolds numbers ranging from the laminar flow regime to fully turbulent flow. The PVDF sensor displayed no discernable response to wall shear. The ionic polymer sensor, however, showed significant response to wall shear and strong correlation with the Reynolds number. In addition, a Stokes oscillating plate apparatus was designed for calibration and testing of the ionic polymer sensor.

Publisher

ASMEDC

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3