Closed-Loop Fluid Resuscitation Control Via Blood Volume Estimation

Author:

Bighamian Ramin1,Kim Chang-Sei1,Reisner Andrew T.2,Hahn Jin-Oh3

Affiliation:

1. Department of Mechanical Engineering, University of Maryland, 2181 Glenn L. Martin Hall, College Park, MD 20742 e-mail:

2. Department of Emergency Medicine, Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114 e-mail:

3. Mem. ASME Department of Mechanical Engineering, University of Maryland, 2181 Glenn L. Martin Hall, College Park, MD 20742 e-mail:

Abstract

This paper presents a closed-loop control of fluid resuscitation to overcome hypovolemia based on model-based estimation of relative changes in blood volume (BV). In this approach, the control system consists of a model-based relative BV (RBV) estimator and a feedback controller. The former predicts relative changes in the BV response to augmented fluid by analyzing an arterial blood pressure (BP) waveform and the electrocardiogram (ECG). Then, the latter determines the amount of fluid to be augmented by comparing target versus predicted relative changes in BV. In this way, unlike many previous methods for fluid resuscitation based on controlled variable(s) nonlinearly correlated with the changes in BV, fluid resuscitation can be guided by a controlled variable linearly correlated with the changes in BV. This paper reports initial design of the closed-loop fluid resuscitation system and its in silico evaluation in a wide range of hypovolemic scenarios. The results suggest that closed-loop fluid resuscitation guided by a controlled variable linearly correlated with the changes in BV can be effective in overcoming hypovolemia: across 100 randomly produced hypovolemia cases, it resulted in the BV regulation error of 7.98 ± 171.6 ml, amounting to 0.18 ± 3.04% of the underlying BV. When guided by pulse pressure (PP), a classical controlled variable nonlinearly correlated with the changes in BV; the same closed-loop fluid resuscitation system resulted in persistent under-resuscitation with the BV regulation error of −779.1 ± 147.4 ml, amounting to −13.9 ± 2.65% of the underlying BV.

Funder

Office of Naval Research

Publisher

ASME International

Subject

Computer Science Applications,Mechanical Engineering,Instrumentation,Information Systems,Control and Systems Engineering

Reference75 articles.

1. Effects of Hemorrhage on Regional Blood Flow Distribution in Dogs and Primates;J. Clin. Invest.,1974

2. Hemodynamics in Hemorrhage: Influences of Sympathetic Nerves and Pentobarbital Anesthesia;Proc. Soc. Exp. Biol. Med. Soc. Exp. Biol. Med. N. Y. N,1971

3. Early Fluid Resuscitation Improves Outcomes in Severely Burned Children;Resuscitation,2000

4. Fluid Replacement in Burned Patients;Acta Chir. Plast.,1996

5. Fluid and Electrolyte Replacement in the Burned Patient;Surg. Clin. North Am.,1978

Cited by 14 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献