Affiliation:
1. National Institute of Forest Science
Abstract
The withdrawal resistance of self-tapping screws (STS) in Korean structural softwood in the vertical fiber direction was examined. Four representative softwood species were selected based on their specific gravity. Three STS fastener diameters were used for an STS penetration depth of 50 mm. The withdrawal capacity tended to increase with the specific gravity of the specimens and as the diameter of the STS increased. Primarily, the difference in strength was maximized as the STS diameter increased from 8 to 10 mm. Predictive experimental equations were proposed based on the experimental values of the relationship between the specific gravity of the structural material and the withdrawal resistance according to the diameter of the STS. The values were compared with the predicted values calculated using fastener and screw prediction equations proposed by the National Design Specification for Wood Construction (NDS) and European Standards (EN). The results calculated using the NDS prediction equations yielded a peak difference of 43% compared with the experimental withdrawal capacity, whereas the EN prediction equations yielded a difference of 0.7 to 1.14 times the experimental values. The ratios between the withdrawal capacity predicted by the proposed prediction equations and the experimental withdrawal capacity were the most similar, ranging from 0.80 to 1.15.
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献