Evaluation of PET quantification accuracy in vivo

Author:

Hofheinz F.,Schramm G.,Oehme L.,Beuthien-Baumann B.,Lukas M.,Buchert R.,Steinbach J.,Kotzerke J.,van den Hoff J.,Maus J.

Abstract

SummaryQuantitative positron emission tomography (PET) requires accurate scanner calibration, which is commonly performed using phantoms. It is not clear to what extent this procedure ensures quantitatively correct results in vivo, since certain conditions differ between phantom and patient scans. Aim: We, therefore, have evaluated the actual quantification accuracy in vivo of PET under clinical routine conditions. Patients, methods: We determined the activity concentration in the bladder in patients undergoing routine [18F]FDG whole body investigations with three different PET scanners (Siemens ECAT EXACT HR+ PET: n = 21; Siemens Biograph 16 PET/CT: n = 16; Philips Gemini-TF PET/CT: n = 19). Urine samples were collected immediately after scan. Activity concentration in the samples was determined in well counters cross-calibrated against the respective scanner. The PET (bladder) to well counter (urine sample) activity concentration ratio was determined. Results: Activity concentration in the bladder (PET) was systematically lower than in the urine samples (well The patient-averaged PET to well counter ratios for the investigated scanners are (mean ± SEM): 0.881 ± 0.015 (ECAT HR+), 0.898 ± 0.024 (Biograph 16), 0.932 ± 0.024 (Gemini-TF). These values correspond to underestimates by PET of 11.9%, 10.2%, and 6.8%, respectively. Conclusions: The investigated PET systems consistently underestimate activity concentration in the bladder. The comparison of urine samples with PET scans of the bladder is a straightforward means for in vivo evaluation of the expectable quantification accuracy. The method might be interesting for multi-center trials, for additional quality assurance in PET and for investigation of PET/MR systems for which clear proof of sufficient quantitative accuracy in vivo is still missing.

Publisher

Georg Thieme Verlag KG

Subject

Radiology, Nuclear Medicine and imaging,General Medicine

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3