Visual Assessment of Factors Affecting Reverse Pressure Gradients in Liners Using a Simulated Milking Device

Author:

Enokidani Masafumi,Inui Yoji,Kondo Hitoshi,Kawai Kazuhiro,Shinozuka Yasunori,Imao Kento

Abstract

Highlights In a simulated milking device, liner internal diameter, pulsation setting, and vent location all affect backflow. Junction point internal diameter affects backflow more than other factors. Vent location has no effect on backflow if the liner internal diameter is large. Backflow is strong with simultaneous pulsation, regardless of other factors. Abstract. The backflow of milk resulting from reverse pressure gradients in liners can cause mastitis. In this study, we hypothesized that liner internal diameter, vent location, and pulsation setting can induce backflow. We therefore attempted to clarify the mechanism of backflow using a flow simulated device. We visually analyzed the effects on backflow of the liner junction point (JP) (i.e., the border from the liner to the short milk tube), the liner inlet point (IP) (i.e., a distance of 63 mm from the end of the short milk tube), vent location, and pulsation setting, using high-speed video recordings of water flow in clear silicone liners at seven flow rates (1.0, 1.5, 2.0, 2.5, 3.0, 3.5, and 4.0 kg min-1/quarter). The actual flow rate was approximately half of the flow meter set value due to the effect of the pulsation closing phase (C+D phase) on quarter level. The results showed that the degree of backflow in liners increased considerably with an increase in flow rate and a decrease in liner internal diameter. The degree of backflow was affected considerably more by JP internal diameter than by IP internal diameter, pulsation setting, or vent location. The degree of backflow was not affected significantly by short milk tube vents and mouthpiece vents when JP internal diameter was larger. However, the degree of backflow was very strong when simultaneous pulsation was used, even at low flow rates. The findings showed that the JP internal diameter should be >13.0 mm, IP internal diameter should be >11.0 mm, the pulsation rate should be 60 pulses/min, and the pulsation ratio should be 60:40 when the alternative pulsation setting is used. This information might be useful for preventing intramammary gland infection. Keywords: Liner internal diameter, Pulsation setting, Reverse pressure gradients, Simulated milking device, Vent location.

Publisher

American Society of Agricultural and Biological Engineers (ASABE)

Subject

Biomedical Engineering,Soil Science,Forestry,Food Science,Agronomy and Crop Science

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3