Abstract

HighlightsAn experiment was conducted to investigate the hydraulic performance of a fixed spray plate sprinkler (FSPS).A model was developed for estimating the cumulative kinetic energy of the FSPS under a moving system.The droplet characteristics and kinetic energy distribution were affected by the working pressure and FSPS structure.A high cumulative kinetic energy could lead to a low water infiltration rate into the soil.Abstract. The kinetic energy of droplets from a fixed spray plate sprinkler (FSPS) has a substantial influence on runoff and soil erosion, as well as on the energy consumption of moving sprinkler irrigation systems. To determine the droplet characteristics and kinetic energy of an FSPS, an experiment was conducted to investigate the effects of working pressure, plate structure, and nozzle size on the droplet diameter, velocity, and kinetic energy. Two plates (the FSPSB with a concave trajectory and deep grooves in the blue plate, and the FSPSY with a flat trajectory and shallow grooves in the yellow plate) were used in the tests. The cumulative kinetic energy and water depth were calculated for a single sprinkler moving in a straight line. The results show that the FSPSB, which had deeper grooves in the plate, produced a larger droplet diameter than the FSPSY, with shallow grooves in the plate. The droplet landing velocities presented a logarithmic relationship with the droplet diameter, and velocities increased with an increase in droplet diameter. The peak specific power (SP) value of the FSPSB was 1.14 to 16.76 times that of the FSPSY. When the working pressure was less than 150 kPa, the peak SP of the FSPSB remained at a high level. With an increase in working pressure, the peak SP of the FSPSB initially increased and then decreased, while the peak SP of the FSPSY increased. The cumulative kinetic energy of the FSPSB was higher than that of the FSPSY under mobile spray conditions. Compared with the cumulative water depth, the cumulative kinetic energy of the FSPSB increased and then decreased as the working pressure increased for the same applied water volume. Because the soil had a lower infiltration rate under the FSPSB, surface ponding was more likely to occur with the FSPSB than with the FSPSY at low working pressure. Keywords: Cumulative kinetic energy, Droplet size, Specific power, Sprinkler irrigation, Working condition.

Publisher

American Society of Agricultural and Biological Engineers (ASABE)

Subject

Soil Science,Agronomy and Crop Science,Biomedical Engineering,Food Science,Forestry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3