Abstract
A simultaneous multi–component analytical method for 37 New psychoactive substances (NPS) in wastewater using LC–MS/MS was developed in this study. Cartridge and solvent tests were conducted to establish the optimal method taking into consideration the polarity and acid–base characteristics of widely distributed NPS. The most efficient pretreatment method was to use HLB cartridge with 2% Formic acid in methanol elution solvent. The developed analytical method was validated by evaluating its specificity, linearity, accuracy, precision (intra and inter), and robustness. The r<sup>2</sup> of calibration curves ranged from 0.9969 to 0.9999, ensuring linearity within the concentration range of 0.5–100 ng/mL. The accuracy for 37 compounds ranged from 72.2 to 114.7%, with an intra–day precision ranging from 0.45 to 11.63% and an inter–day precision ranging from 0.96 to 17.99%. The MDL was in the range of 0.01–2.91 ng/L and the LOQ was 0.03–9.71 ng/L. Robustness was evaluated to test the stability of the final solutions, and all compounds were assessed over 36 h and 30 days. The developed analytical method was applied to wastewater samples collected from six Korean WWTPs, and five compounds were detected.
Funder
Ministry of Food and Drug Safety
National Research Foundation of Korea
Ministry of Education
Publisher
Korean Society of Environmental Engineering
Subject
Environmental Engineering
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献