Affiliation:
1. Building Research Establishment UK
2. Roger Bullivant Ltd
3. South Bank University
4. Formerly South Bank University
Abstract
Full-scale instrumented load tests have been carried out to study the installation and performance of vibro stone columns supporting a strip foundation in a variable fill and the performance of a similar strip foundation on untreated ground. The results from site investigation and laboratory testing are presented, and the vibro design principles—in particular the use of a modification to a standard formula that reflects the radial densification of soil around the stone column—are outlined. The treated foundation performance is compared with predicted behaviour; calculated settlements are in reasonable agreement with measured values, but stress measurements suggest that current design assumptions significantly overestimate the degree of stress concentration on the stone columns. The degree of radial densification of fill around the stone columns varied according to installation technique and soil type. The implications of the trial observations for existing design methods are considered.
Subject
Earth and Planetary Sciences (miscellaneous),Geotechnical Engineering and Engineering Geology
Cited by
64 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献