Zone coulometry and ion-release analysis of degradable magnesium alloys

Author:

Schille Christine1,Schweizer Ernst2,Hort Norbert3,Reichel Heinz-Peter4,Geis-Gerstorfer Jürgen5

Affiliation:

1. Technical assistant of physics, Dental Clinic, Section Medical Materials and Technology, University Hospital of Tuebingen, Tuebingen, Germany

2. Technical assistant of chemistry, Dental Clinic, Section Medical Materials and Technology, University Hospital of Tuebingen, Tuebingen, Germany

3. Head of department magnesium processing, Magnesium Innovation Center, Helmholtz-Zentrum Geesthacht, Geesthacht, Germany

4. General manager, Weisensee Warmpressteile GmbH, Eichenzell, Germany

5. Chairman of Section Medical Materials and Technology, University Hospital of Tuebingen, Tuebingen, Germany

Abstract

Zone coulometry and determination of ion release of an electrolyte from anodic polarization measurements are the established calculation modes for the electrochemical behavior of dental and biomedical alloys. The aim of the study was to compare the electrochemical corrosion behavior of six different experimental magnesium alloys without manganese using artificial plasma (AP) and in phosphate-buffered saline (PBS) as simulated body fluids through anodic polarization measurements. In addition, determination of the magnesium release of the electrolytes was performed using inductively coupled plasma optical emission spectrometry and zone coulometry. Six specimens were prepared from each alloy. Anodic polarization measurements ranging from –150 mV ~Ecorr to –1200 mV were performed with both of the electrolytes. From each measurement, corrosion current density, the breakdown or pitting potential and its corresponding current density, zero potential, the polarization resistance, the corrosion rate were calculated. The magnesium release of the electrolytes was compared with the calculated values using Faraday’s law. For zone coulometry, five different trials were completed, and the electrical charge was calculated for each potential range of all magnesium alloys tested and for both electrolytes. Lower corrosion values were found in AP than in PBS for all measurements. However, the rankings of the alloys are similar in both the electrolytes. Zone coulometry using small potential ranges and determination of ion release can be additional evaluation tools for magnesium alloys.

Publisher

Thomas Telford Ltd.

Subject

Condensed Matter Physics,General Materials Science

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3