Abstract

Trombe walls are the most widely applied passive systems that utilise solar energy for heating massive walls. Although studies have been undertaken in the fields of Trombe wall application and design, the research on the effect of the vent area and the number of vents on the performance of a Trombe wall remains limited. In this context, a parametric study investigating the effect of the vent-to-wall-area ratio on Trombe wall performance was conducted. A computational fluid dynamics model was employed for validation analysis. The results were verified by experimental measurements of temperature. At each step of the parametric study, the vent-to-wall-area ratio in the Trombe wall model was increased by 2% starting from the unvented case, and the results were simulated per ratio. In this study, temperature measurements of the glazing, thermal wall and space were employed as the evaluation criteria. The results of the parametric runs showed that a Trombe wall with eight separate air vents and an 8% vent-to-wall-area ratio provides the maximum heating performance. Furthermore, a monolithic vent configuration with an 18% vent-to-wall-area ratio performed slightly better compared with other configurations of monolithic air vents.

Publisher

Thomas Telford Ltd.

Subject

Civil and Structural Engineering

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Optimal Specifications of a Trombe Wall in Low-Rise Residential Buildings of Mashhad;Applied Solar Energy;2023-08

2. Comparison of Energy, Economy, and Environmental Analysis Results of Different Types of Trombe Walls for Manisa;Bilecik Şeyh Edebali Üniversitesi Fen Bilimleri Dergisi;2023-05-31

3. Türkiye’deki Trombe Duvarı Sistemine ait Sayısal Isı Akışı Analizi;Uludağ University Journal of The Faculty of Engineering;2022-08-16

4. Effect of air gap depth on Trombe wall system using computational fluid dynamics;International Journal of Low-Carbon Technologies;2022

5. Editorial;Proceedings of the Institution of Civil Engineers - Engineering Sustainability;2021-10

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3