Abstract
Synopsis This article describes model experiments performed at the Building Research Station to determine the type of failure occurring in strutted sheeted excavations in non-cohesive soils due to seepage water. Model excavations were constructed in a seepage tank fitted with glass sides and with pressure points through the tank base. Observations were taken to determine the flow net and to follow the mode of failure of the soil under various conditions. The factors which were varied include the width of the cofferdam, the depth of penetration of the sheeting, and the soil conditions. Tests were carried out with homogeneous sand in both dense and loose packing and various combinations of different soil strata were also used. The results are discussed and tentative suggestions for design are put forward. Cet article décrit des expériences modèles qui ont été faits à la Centrale pour le Recherche de la Construction pour déterminer le type de l'insuccès qui se présente dans les excavations entretoisées tôlées dans les sols non-cohésives à cause de suintement de l'eau. Des excavations modèles étaient construites dans un rérvoir à suintement muni de côtés en verre et ayant des points de pression à travers la base du réservoir. Des observations étaient prises pour déterminer 1'8coulement net et pour suivre la mode de défaut du sol sous les conditions diverses. Les éléments qui étaient variés comprennent la largeur du caisson, la profondeur de la pénétration de la tôlerie et les conditions du sol. Des essais étaient faits avec du sable homogéneux dans un tassement dense aussi bien que dans un tassement lâche et des combinaisons de strata divers de sols étaient aussi utilisées. Les résultats sont considérés et des suggestions tentatives pour le projet sont soumises.
Subject
Earth and Planetary Sciences (miscellaneous),Geotechnical Engineering and Engineering Geology
Cited by
31 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献