Affiliation:
1. Universidad Nacional Autónoma de Mexico; Centro Nacional de Investigaciones Metalúrgicas
Abstract
Corrosion at the steel-mortar interface in reinforced concrete structures was studied by use of the coulostatic method. The corrosion rate and double-layer capacitance thus obtained were consistent with those provided by other, more common electrochemical methods. The coulostatic method provides more reliable data for corrosion in the passive state as a result of the measuring electrode being perturbed to a much lesser extent than with the other methods.
Subject
General Materials Science,Building and Construction,Civil and Structural Engineering
Cited by
26 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献