Affiliation:
1. National University of Singapore
Abstract
The effects of embedded steel bars on the strength of concrete cylinders as affected by various parameters were investigated. These parameters were the size and the length/diameter ratio of the cylinders, the positioning of the steel bar, the bar size and the cube strength of concrete. For a length/diameter ratio of 1·0, the experimental results differed significantly from the calculated values based on the correction formula recommended in BS 1881, Part 120. The inclusion of steel up to 4% by volume in 100 mm × 100 mm cylinders did not have any detrimental effect, but for deformed high tensile steel bars of 13–20 mm diameter, increases of up to 9% in the measured strengths over those of the control specimens were observed.
Subject
General Materials Science,Building and Construction,Civil and Structural Engineering
Cited by
15 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献