Numerical analysis of field geosynthetic-reinforced retaining walls with secondary reinforcement

Author:

Jiang Y.1,Han J.2,Zornberg J.3,Parsons R. L.2,Leshchinsky D.4,Tanyu B.5

Affiliation:

1. Formerly University of Kansas; now Terracon Consultants, Inc., Savannah, Georgia, USA.

2. Department of Civil, Environmental & Architectural Engineering, The University of Kansas, Lawrence, KS, USA.

3. The University of Texas at Austin, Austin, TX, USA.

4. ADAMA Engineering, Inc., Clackamas, OR, USA.

5. George Mason University, Fairfax, VA, USA.

Abstract

Geosynthetic-reinforced retaining (GRR) walls typically have vertical reinforcement spacing of 0·6 m, and this relatively large spacing has been known to cause comparatively high connection forces. To reduce this connection force, short geosynthetic reinforcement layers (referred to as secondary reinforcement layers) are installed between blocks where there are no primary reinforcement layers. This paper presents two-dimensional numerical simulations that were developed to analyse an instrumented GRR wall with secondary reinforcement layers in the field. A finite differential software was employed to develop the numerical model. In addition to the Mohr–Coulomb model, the cap yield model based on the theory of hardening plasticity was used to represent the behaviour of backfill. Inclinometer casings, earth pressure cells and strain gauges were installed in the instrumented GRR walls to measure the facing deflections, lateral earth pressures, vertical earth pressures and geogrid strains. The measured results and numerical predictions were compared and discussed, and reasonable agreement between these results was found. Compared to the measured results, the numerical predictions slightly underestimated the maximum wall facing deflections and vertical earth pressures, and slightly overestimated lateral earth pressures and strains in primary and secondary reinforcement layers. For comparison, a numerical model without secondary reinforcement was developed as well. This comparison revealed that the GRR wall with secondary reinforcement resulted in smaller facing deflections and maximum strains in primary reinforcement layers. Overall, the numerical analysis indicated that secondary reinforcement could provide clear benefits in improving the performance of GRR walls.

Publisher

Thomas Telford Ltd.

Subject

Earth and Planetary Sciences (miscellaneous),Geotechnical Engineering and Engineering Geology

Reference26 articles.

1. Christopher, B. R., Gill, S. A., Giroud, J. P., Juran, I. Scholsser, F., Mitchell, J. K. & Dunnicliff, J. (1989). Reinforced soil structures, volume II. Summary of research and systems information, Report No. FHWA-RD-89-043. Washington, DC, USA: Federal Highway Administration.

2. Duncan, J. M., Byrne, P. M., Wong, K. S. & Mabry, P. (1980). Strength, stress–strain and bulk modulus parameters for finite element analyses of stresses and movements in soil masses, Report No. UCB/GT/80-01. Berkeley, CA, USA: Department of Civil Engineering, University of California.

3. Numerical analysis of reinforced soil-retaining wall structures with cohesive and granular backfills

Cited by 48 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献