Affiliation:
1. Chalmers Tekniska Högskola, Göteborg
2. Politecnico di Torino
3. Openbare Werken Amsterdam
Abstract
A theory is described which can be used in designing a vertical drainage system. This theory incorporates important parameters such as vertical discharge capacity, remoulding effects during installation and filter resistance. The importance of these parameters is widely recognized, but very seldom taken into account in the design, by engineers. Six well-documented case records, related to different drain types are briefly presented. Experience gained from these case records shows that in many cases, even if the overall performance appears successful, there are aspects of soil/drain behaviour that cannot be explained on the basis of existing theories. L'article décrit une théorie que l'on peut appliquer à la conception d'un système de drainage vertical. Cette théorie renferme d'importants paramètres tels que la capacité de décharge verticale, les effets du remaniement pendant l'installation et la résistance de filtration. L'importance de ces paramètres est reconnue par bien des ingénieurs, mais ils en tiennent rarement compte au stade de la conception. L'article donne une description sommaire de six cas bien documentés dans lesquels divers types de drains sont utilisés. L'expérience acquise grâce à cette étude de cas montre que, très souvent, même si l'efficacité globale semble satisfaisante, il existe certains aspects du comportement sol/drains que l'on ne peut expliquer sur la base des théories existantes.
Subject
Earth and Planetary Sciences (miscellaneous),Geotechnical Engineering and Engineering Geology
Cited by
113 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献