Affiliation:
1. School of Civil and Structural Engineering, Nanyang Technological University Singapore
Abstract
A parametric study on the ultimate load carrying capacity of a tubular T-joint reinforced with a doubler plate is presented. The reinforced T-joint was modelled using the finite element method and was subjected to the four basic loading conditions. The ultimate strength of the reinforced joint was compared to design equations for the prediction of ultimate strength of conventional T-joints to determine the strengthening effect of the doubler plate. The doubler plate was found to increase the ultimate capacity of axially loaded joints by up to 150% and joints subjected to bending by 75%. A set of empirical equations was proposed to predict the ultimate capacities of the doubler plate reinforced T-joint.
Subject
Building and Construction,Civil and Structural Engineering
Reference23 articles.
1. American Welding Society. Structural Welding Code—Steel, 1992, 14th edn., ANSI/AWS D1, Miami, 1–92.
2. Ultimate Resistance of Unstiffened Tubular Joints
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献