Velocity encoded mitral valve inflow cine: A novel and more reproducible method to determine cardiac rest periods during coronary magnetic resonance angiography

Author:

Markus Richard12,Tandon Animesh3ORCID,Fares Munes12,Dillenbeck Jeanne4,Greil Gerald F.124,Batsis Maria1,Greer Joshua124,Potersnak Amanda5,Zhang Song6,Hussain Tarique124,Avula Sravani12ORCID

Affiliation:

1. Department of Pediatrics, University of Texas Southwestern Medical Center, Dallas, Texas, USA

2. Division of Pediatric Cardiology, Children’s Medical Center Dallas, Dallas, Texas, USA

3. Department of Pediatric Cardiology and Director of Cardiovascular Innovation, Cleveland Clinic Children’s Hospital, Cleveland, Ohio, USA

4. Departments of Radiology and Biomedical Engineering, University of Texas Southwestern Medical Center, Dallas, Texas, USA

5. National Institutes of Health, Bethesda, Maryland, USA

6. Department of Clinical Sciences, University of Texas Southwestern Medical Center, Dallas, Texas, USA

Abstract

A high temporal resolution, 4-chamber (4CH) cine is the standard method for determining cardiac rest periods during whole heart coronary magnetic resonance angiography (CMRA). We evaluated the image quality and reproducibility between the 4CH cine method and a novel approach using a velocity encoded mitral valve inflow cine (MVI). The goal of this study was to compare the quality of CMRAs utilizing MVI versus 4CH methods. Sharpness and vessel length for the LCA and RCA using each method were determined using Soap Bubble and two blinded observers independently assessed coronary image quality. Offline analysis on a separate, retrospective cohort (n = 25) was used to compare MVI and 4CH reproducibility. In the prospectively evaluated cohort there was no difference in overall vessel sharpness (4CH vs MVI mean ± SD) (31.0 ± 5.5% vs 30.5 ± 5.7%, p = .63), LCA vessel sharpness (30.0 ± 5.4% vs 31.1 ± 8.2%, p = .44), LCA length (4.7 ± 1.4 cm vs 4.6 ± 1.6 cm, p = .66), RCA vessel sharpness (32.1 ± 6.9% vs 31.1 ± 7.7%, p = .55), RCA length (5.51 ± 2.6 cm vs 5.95 ± 2.4 cm, p = .38), or image quality rating (2.66 vs 2.62, p = .80) between methods. In the retrospective cohort, the MVI method had 5.4% lower inter-observer variability (95% CI 3.7,7.2%, p < .0001) and 3.9% lower intra-observer variability (95% CI 2.4,5.4%, p < .0001) than the 4CH method. MVI is a technically feasible and more reproducible method to determine cardiac rest periods compared to 4CH while preserving vessel sharpness, vessel length & image quality.

Publisher

SAGE Publications

Subject

General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Enhanced Machine Learning Model for Design and Evaluation of Various Algorithms Applied in Clinical Cardiovascular Disease;2022 Fifth International Conference on Computational Intelligence and Communication Technologies (CCICT);2022-07

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3