Accuracy and Clinical Correlates of Two Different Methods for Chromogranin A Assay in Neuroendocrine Tumors

Author:

Ferrari L.1,Seregni E.1,Lucignani G.2,Bajetta E.3,Martinetti A.1,Aliberti G.1,Pallotti F.1,Procopio G.2,Torre S. Della3,Luksch R.4,Bombardieri E.1

Affiliation:

1. Nuclear Medicine Unit, Istituto Nazionale per lo Studio e la Cura dei Tumori, Milan

2. Institute of Radiological Sciences, University of Milan and Unit of Molecular Imaging, Division of Radiation Therapy, European Institute of Oncology, Milan - Italy

3. Medical Oncology Unit 2, Istituto Nazionale per lo Studio e la Cura dei Tumori, Milan

4. Pediatric Oncology Unit, Istituto Nazionale per lo Studio e la Cura dei Tumori, Milan

Abstract

Measurement of chromogranin A (CgA) plays a major role in the management of neuroendocrine tumors (NET); however, reliable assaying of CgA is made difficult by the rapid hydrolysis following its release into the bloodstream. This study was aimed at the assessment of two assays for CgA in NET patients. CgA was measured in 93 patients by means of an enzyme-linked immunosorbent assay (ELISA) and an immunoradiometric assay (IRMA). The specificity and sensitivity of CgA were evaluated in relation to tumor histology. The clinical accuracy of the two assays was evaluated by receiver-operating characteristic (ROC) curve analysis. Regression analysis demonstrated different immunoreactivity for CgA of the antibodies used in the two kits (r=0.61). The two assays had different accuracy also in classifying patients according to their clinical condition (91% vs 64% specificity and 79% vs 79% sensitivity for the ELISA and IRMA assay, respectively) and tumor histology (81% vs 85% sensitivity for the ELISA and IRMA assays, respectively, in carcinoids; 92% vs 67% sensitivity for the ELISA and IRMA assays, respectively, in pancreatic islet cell tumors). The different clinical accuracy of the two assays was confirmed by the ROC analysis (AUC=0.90 vs AUC=0.87 for the ELISA and IRMA assays, respectively). In conclusion, because of the poor standardization of the commercially available measurement tools the clinical accuracy of CgA measurement depends on the assay used. This makes it difficult to compare CgA values measured with different kits and affects the clinical accuracy of the different assays for CgA.

Publisher

SAGE Publications

Subject

Cancer Research,Clinical Biochemistry,Oncology,Pathology and Forensic Medicine

Cited by 26 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3