Assessment of the Biological Variation of Plasma Tissue Inhibitor of Metalloproteinases-1

Author:

Frederiksen C.B.1,Lomholt A.F.1,Lottenburger T.2,Davis G.J.3,Dowell B.L.3,Blankenstein M.A.3,Christensen I.J.4,Brünner N.5,Nielsen H.J.1

Affiliation:

1. Department of Surgical Gastroenterology, Hvidovre University Hospital, Hvidovre - Denmark

2. Rheumatism Hospital, University of Southern Denmark, Graasten - Denmark

3. Abbott Laboratories, Abbott Park, Illinois - USA

4. Department of Clinical Chemistry, VU Medical Center, Amsterdam - The Netherlands

5. The Finsen Laboratory, Rigshospitalet, Copenhagen Biocenter, Copenhagen - Denmark

Abstract

Background Tissue inhibitor of metalloproteinases-1 (TIMP-1) measurements in plasma may be useful for the early detection and prognosis of colorectal cancer (CRC). Data on analytical performance and normal intra- and interindividual biological variation are required in order to interpret the utility of TIMP-1 in CRC. The aim of this study was to establish the biological and analytical variation of plasma TIMP-1 in volunteers. Material and methods Three separate studies were undertaken. 1: Plasma was collected from 23 volunteers 6 times within a 3-week period, first in September 2004 (round [R] 1), then repeated in May 2005 (R2) and May 2006 (R3) in the same group of individuals. TIMP-1 levels were determined by the MAC15 ELISA assay and with the Abbott ARCHITECT i2000 Immunoanalyzer. 2: Circadian variation was evaluated in plasma collected 7 times within a 24-hour period (n=16). 3: Effects of physical exercise were evaluated in plasma collected before and after bicycling (n=14). In studies 2 and 3 TIMP-1 levels were determined with the MAC15 ELISA assay only. Results A significant correlation between TIMP-1 MAC15 and ARCHITECT i2000 was shown (rs=0.78, p<0.002), with consistently higher levels being detected by the ARCHITECT i2000. Median levels of TIMP-1 (ARCHITECT) at 8 a.m. in each round were 74.9 ng/mL (range 65.7–89.9) (R1), 87.3 ng/mL (range 72.7–127.9) (R2), and 81.9 ng/mL (range 66.8–113.6) (R3). The within-subject variation was 10.7%, the variation between rounds was 7.4%, and the intraclass correlation was 46.2%. Comparison between the 3 rounds and time of collection showed that TIMP-1 values decreased by 11% after storage for more than 16 months (p=0.0002). A systematic circadian variation in plasma TIMP-1 levels was not observed (p=0.17). No significant variation of plasma TIMP-1 was found in relation to physical exercise (p=0.92 [global test]). Conclusion Levels of plasma TIMP-1 in volunteers show limited circadian, day-to-day, week-to-week and season-to-season variation. In addition, physical exercise has no impact on plasma TIMP-1 levels. Possible storage-dependent decreases in plasma TIMP-1 levels warrant further investigation.

Publisher

SAGE Publications

Subject

Cancer Research,Clinical Biochemistry,Oncology,Pathology and Forensic Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3