Comparison Between Time-Resolved Magnetic Resonance Angiography and Diagnostic Digital Subtraction Angiography in the Vascular Assessment of Nonspecific Aorto-Arteritis Patients: A Prospective Study

Author:

Chandrashekhara Sheragaru Hanumanthappa1,Gulati Gurpreet Singh1,Sharma Sanjiv1,Jagia Priya1,Kumar Sanjeev1,Choudhary Shiv2

Affiliation:

1. Department of Cardiovascular Radiology & Endovascular Interventions, All India Institute of Medical Sciences, New Delhi, India

2. Department of Cardiothoracic and Vascular Surgery, All India Institute of Medical Sciences, New Delhi, India

Abstract

Purpose: Nonspecific aortoarteritis (NSAA) is a chronic inflammatory vasculitis involving aorta and its branches. We conducted a study prospectively to compare time resolved magnetic resonance angiography (MRA) with diagnostic digital subtraction angiography (DSA) for the vascular assessment in the patients of NSAA. Materials and Methods: Seventeen patients of NSAA were recruited in the study over the period of 3 years. Contrast enhanced MRA using Time-resolved angiography With Interleaved Stochastic Trajectories (TWIST) sequence and diagnostic DSA were performed in these 17 patients. Results: The majority of the patients were young (median age was 25 years, range 8 to 46 years) and 11 patients were females. Erythrocyte sedimentation rate (ESR) was elevated in 9 patients and C-reactive protein (CRP) was elevated in 6 patients. Most commonly involved vessels in our patients were right renal artery (14 patients), abdominal aorta (12 patients) and left renal artery (11 patients). Left and right subclavian arteres were involved in 10 and 6 patients respectively. The sensitivity and specificity of time-resolved MRA using TWIST sequence is 100% as compared to DSA in the assessment of major vessels such as aorta, arch vessels, celiac artery and superior mesenteric artery. However, the sensitivity and specificity of time resolved MRA in the evaluation of renal arteries and vertebral arteries were 100%, 71.4% and 85.7%, 33.3% respectively. No significant association of MRI contrast enhancement with erythrocyte sedimentation rate (p = 1.00) and C-reactive protein (p = 0.600). Conclusion: Time resolved MRA images obtained using TWIST sequence were as qualitative as DSA images and can noninvasively evaluate the vascular involvement in NSAA patients.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,General Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3