Affiliation:
1. Departments of General Surgery and Nephrology, University of Uludag, Bursa, Thrkey
Abstract
The authors review their experience with 318 direct radiocephalic arteriovenous fistulas created for chronic maintenance hemodialysis over the past six years. Thirty-five of the fistulas (11 %) never functioned or thrombosed within the first month. The early failure rate was significantly different between groups older and younger than fifty years of age (p < 0.05). Moreover, the early thrombosis rate was related to the suture techniques used: 8.62% for the interrupted suture group and 20.63% for the running suture group (p < 0.05). Average patency duration for still functioning fistulas in 120 patients is 38.8 months; for the 58 patients who had late failure it was 14.9 months.
Subject
Cardiology and Cardiovascular Medicine
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献