Outcomes of Endovascular AAA Repair in Patients with Hostile Neck Anatomy Using Adjunctive Balloon-Expandable Stents

Author:

Cox Daniel E.,Jacobs Donald L.,Motaganahalli Raghunandan L.,Wittgen Catherine M.,Peterson Gary J.1

Affiliation:

1. St. Louis, MO

Abstract

Hostile neck anatomy remains the predominant reason that patients are denied endovascular aneurysm repair (EVAR). We reviewed our experience of EVAR with use of prophylactic adjunctive proximal balloon-expandable stents in patients with hostile neck anatomy and adjunctive proximal balloon-expandable stents in patients with type I endoleaks. Of 140 patients who underwent EVAR between 2000 and 2004, we reviewed data for 19 patients in whom we used proximal balloon-expandable stents. By high-resolution computed tomography scan or angiography, hostile neck anatomy was classified as length <15 mm, neck diameters = 26 mm, circumferential thrombus at the proximal neck, angulated neck =60 degrees, and neck bulge or reverse taper necks. Patients were considered to have hostile anatomy if they met 1 or more of the above-cited criteria. All patients underwent AAA repair with commercially available endograft systems, Zenith (Cook, Bloomington, IN) and AneuRx (Medtronic/AVE, Minneapolis, MN). Balloon-expandable stents utilized included Cordis-Palmaz stents (17/19) and eV3 Max stents (2/19). Stents were deployed in the proximal graft with transrenal extension. AneuRx (18/19) and Zenith (1/19) endografts were used in all of the patients. Of the 19 patients, 15 had prophylactic stent placement for known hostile neck anatomy and 4 patients had stent placement for type I endoleak. Assisted primary technical success was achieved in all patients. Three patients had maldeployment of the endograft or proximal stent requiring additional endovascular interventions at the time of surgery. No endografts were deployed too low requiring stent placement. Procedure-related complications occurred in 2 of 19 patients. These included 1 operative death secondary to pneumonia and 1 patient who developed progressive renal failure. Short-term clinical success was achieved in 17 of 19 patients. Two patients required secondary interventions, 1 due to device migration with secondary conversion to open repair, and an endoleak, which, on angiogram, was a large type II endoleak successfully treated with coiling of the inferior mesenteric artery. One patient was observed to have a type II endoleak with no associated aneurysm enlargement. Short-term results suggest the use of prophylactic adjunctive balloon-expandable stents may decrease the incidence of secondary interventions related to hostile neck anatomy when used as an adjunctive measure with EVAR. Based on our experience, we feel EVAR may be offered to an expanded patient population with hostile neck anatomy with use of prophylactic balloon-expandable stents.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,General Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3