Noninvasive Measurement of Shear Rate in Autologous and Prosthetic Bypass Grafts

Author:

Setty Shaun P.1,Salles-Cunha Sergio2,Scissons Robert,Begeman Garett,Farison James,Beebe Hugh G.1

Affiliation:

1. Jobst Vascular Center, Toledo, Ohio

2. Jobst Vascular Center, 2109 Hughes Dr., Suite 400, Toledo, Ohio 43606

Abstract

There is a major difference in thrombogenicity between lower extremity prosthetic and autologous vein bypass grafts, and arterial blood flow shear rate is known to influence thrombus formation. Despite this association, there has been little direct clinical observation of shear rates in bypass grafts. The authors developed a new noninvasive method to quantitate human arterial shear rate and used it in a pilot study to characterize differences in lower extremity bypasses. Shear rates were measured in 10 prosthetic and 14 autologous vein femoropopliteal bypass grafts. With CVI-M-mode color flow ultrasonography in resting supine patients, a velocity profile was recorded from a midgraft longitudinal section in the ultrasound beam direction. Shear rates were calculated by using a mathematical-graphic computer program at the anteromedial (near) and posterolateral (far) graft walls by averaging values immediately before and after peak systolic velocity (PSV). Comparison between prosthetic and autologous graft groups respectively revealed that differences in age (67 ± [S] vs 71 ± 10 yr), male gender (60% vs 43%), prevalence of hypertension (50% vs 71%), diabetes (40% vs 64%), smoking (50% vs 50%), hypercholesterolemia (30% vs 29%), coronary artery disease (60% vs 50%), and critical ischemia (60% vs 86%) did not reach statistical significance (p>0.19). Median PSVs were significantly less in prosthetic than in autologous vein bypasses (37 ± 13 vs 57 ±22 cm/s, p = 0.018). Prosthetic and autologous graft diameters were not statistically significantly different (6.3 ± 1.1 vs 5.6 ± 1.3 mm, p = 0. 18). Shear rates were significantly less in prosthetic than in autologous vein bypasses both at the near wall (382± 146 vs 698 +271 s-1, p=0.003) and at the far wall (551 ±235 vs 827 ±339 s-1, p=0.037). This mathematical model can be used to calculate shear rate from observed ultrasound flow patterns. Prosthetic bypass grafts had lower shear rates than autologous vein grafts.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,General Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3