Angiographic Analysis of Vascular Integrity After Percutaneous Closure Using Prostar XL Device During Transcatheter Aortic Valve Implantation

Author:

Lareyre Fabien12,Raffort Juliette2,Dommerc Carine1,Benhammamia Mohamed1,Bourlon François1,Habib Yacoub1,Mialhe Claude1

Affiliation:

1. Cardiothoracic Centre of Monaco, Monaco, France

2. University of Côte d’Azur, INSERM, CNRS, IRCAN, Nice, France

Abstract

Introduction: Percutaneous closure devices are commonly used to achieve hemostasis during endovascular procedures including transcatheter aortic valve implantation (TAVI). The aim of our study was to investigate the quality of the percutaneous femoral arterial closure by Prostar XL device using a systematic peroperative angiographic control at the end of TAVI procedure. Materials and Methods: Two hundred seventeen consecutive patients (mean age: 84 [6.5]; 112 women and 105 men) undergoing TAVI with percutaneous transfemoral access were prospectively registered in our center. Preoperative computed tomography scan was performed, and mean femoral vessel diameter was 7.9 (0.9) mm. At the end of TAVI intervention, the hemostasis was systematically achieved using the percutaneous closure device Prostar XL, without selection of patients based on anatomical criteria. An angiography with front and oblique views was performed to evaluate the quality and the safety of the closure device. Success of the percutaneous closure was defined as the absence of hemorrhage and the restitution of the arterial anatomy. Complications related to the percutaneous closure were classified as stenosis, dissection at the puncture site, suture failure, misplacement, or persistent bleeding. Results: Twenty-three (10.6%) patients had complications related to arterial percutaneous closure—14 (60.8%) stenosis, 6 (26.1%) persistent bleeding, and 1 (4.3%) dissection. These lesions were accessible to endovascular treatment via a crossover procedure. One (4.3%) suture failure and 1 (4.3%) misplacement of the device, with a puncture site created above the femoral arch, were reported. The patient developed a retroperitoneal hematoma postoperatively and required transfusion of 2 units of red blood cells associated with a cutdown to remove hematoma and to repair the common femoral artery. Conclusion: Angiography after arterial percutaneous closure using Prostar XL device during TAVI allows detection and endovascular treatment of vascular complications and is associated with low rate of conversion to open surgery.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,General Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3