Computed Tomography Angiography in the Assessment of Great Saphenous Vein as Conduit for Infrainguinal Bypass Surgery

Author:

Belvedere Shane1ORCID,Gouil Quentin23,Thompson Corey14,Solomon Jarryd567

Affiliation:

1. Department of Vascular Surgery, Royal Melbourne Hospital, Parkville, Australia

2. Epigenetics and Development Division, The Walter and Eliza Hall Institute of Medical Research, Parkville, Australia

3. Department of Medical Biology, The University of Melbourne, Parkville, Australia

4. Department of Radiology, Alfred Health, Melbourne, Australia

5. Department of Vascular Surgery, Alfred Health, Melbourne, Australia

6. Department of Vascular Surgery, Austin Health, Heidelberg, Australia

7. Department of Vascular Surgery, Peninsula Health, Frankston, Australia

Abstract

Introduction:The great saphenous vein (GSV) is commonly used as a conduit during infrainguinal bypass (IIB) and is usually well seen on computed tomography angiography (CTA) which is frequently performed for preoperative planning. In this study, we asked whether CTA could replace ultrasonography (US) as the primary mode of conduit assessment, by comparing GSV measurements for patients who underwent both CTA and US vein mapping prior to IIB.Methods:All IIB that were completed in the six-and-a-half-year period from January 1, 2012, to July 31, 2018, at the authors’ institution were examined. Great saphenous vein measurements were analyzed for patients who had undergone both CTA and US vein mapping. Correlation between the measurements was calculated with the Pearson correlation coefficient. Data were then examined using Bland-Altman plots. Then categorical analysis was used to determine the adequacy of GSV for use as a bypass conduit.Results:There were 302 patients who underwent IIB, with 73 legs, in 47 patients, examined with CTA and US. Computed tomography angiography and US measurements were moderately correlated ( r = 0.531) across all measurement locations. Correlation progressively reduced distally (proximal thigh r = 0.534, midthigh r = 0.536, knee r = 0.35, midcalf r = 0.185, P = .074, ankle r = 0.078, P = .485). Bland-Altman plots of the pooled location data demonstrated no systematic bias. However, the upper and lower limits of agreement were wide, between −2.02 and +2.37 mm, demonstrating a lack of agreement between CTA and US. Analysis of each location revealed similar findings. A receiver operator characteristic curve was constructed based on a minimum US GSV diameter for adequate bypass conduit of 3 mm. The CTA value that maximized the Youden index was 3.8 mm.Conclusion:The level of error between CTA and US measurements, demonstrated by the large limits of agreement on Bland-Altman plots, would not be clinically acceptable. However, if a larger threshold is accepted, CTA has the potential to replace preoperative US vein mapping of GSV.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,General Medicine,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Peripheral Artery Disease: Why Do We Need CT Imaging?;Journal of the Belgian Society of Radiology;2024

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3